Water Pipe Size Calculator: Flow and Pressure Loss
Enter the flow, the run length and the pipe type. See the water velocity and pressure loss for every common size, and the smallest size that stays inside your limits.
Quick answer
Water velocity in feet per second is 0.4085 x gpm divided by the pipe's inside diameter squared, and friction loss follows the Hazen-Williams formula. Many designers keep cold water at or under 8 ft/s. At 6 gpm, 1/2 inch copper runs at about 8.3 ft/s, so 3/4 inch is the smallest size that fits.
Smallest size that fits
3/4 in
- 1/2 in
- 8.25 ft/s, 29.35 psi (over limit)
- 3/4 in
- 3.98 ft/s, 4.96 psi
- 1 in
- 2.33 ft/s, 1.35 psi
- 1-1/4 in
- 1.53 ft/s, 0.49 psi
- 1-1/2 in
- 1.08 ft/s, 0.21 psi
- 2 in
- 0.62 ft/s, 0.05 psi
Hazen-Williams friction loss and velocity for Copper, type L with C = 130, using conservative inside diameters. This sizes for a known flow; plumbing codes size supply pipes by fixture units, which this does not replace. Check the manufacturer's inside diameters and your code.
Opens the free invoice maker with this as the first line. Add your rate and download the PDF.
What this calculator does and does not do
It takes a flow you already know and shows what that flow does inside each pipe size: how fast the water moves and how much pressure it loses over the run. That is the physics behind a sizing decision. It is not the code method. Plumbing codes size supply piping by fixture units, available pressure and developed length, using their own tables, and your local code decides what is acceptable. Use this to check and price a job, and confirm sizes against your code.
The formulas
- Velocity (ft/s) = 0.4085 x flow (gpm) / inside diameter (in) squared
- Friction loss (psi per foot) = 4.52 x gpm to the 1.85 / (C to the 1.85 x inside diameter to the 4.87)
- Total loss (psi) = psi per foot x run length (ft)
The assumptions it uses
Inside diameters and the friction factor C vary between sources, and the result is sensitive to diameter. Where values differ, this calculator uses the smaller diameter and the lower C, so the loss shown is on the safe side. Copper is type L with C of 130. PEX uses C of 140 and inside diameters at the small end of the published range. PVC is schedule 40 with C of 140. Check the manufacturer's inside diameters for the product you install.
A worked example
At 5 gpm through 3/4 inch type L copper (inside diameter 0.785 inch), velocity is 0.4085 x 5 / 0.616, which is 3.31 ft/s. Friction loss is about 0.0355 psi per foot, so a 100 foot run loses about 3.55 psi. The same flow in 1/2 inch copper runs at 6.9 ft/s, which is under 8 but with a much higher loss.
Water Pipe Size Calculator questions
01How do I size a water supply pipe?
Find the flow of the fixtures that run together, then check the velocity and friction loss in each pipe size and pick the smallest one inside your limits. Plumbing codes use fixture units and their own tables, so confirm the result against the code that applies.
02What is the maximum water velocity in a pipe?
Designers commonly keep cold water at or under about 8 feet per second and hot water at or under about 5, to limit noise and wear. Your code or the pipe manufacturer may set different limits.
03How do I calculate pressure loss in a pipe?
Use the Hazen-Williams formula: psi per foot equals 4.52 x gpm to the 1.85 divided by C to the 1.85 x inside diameter to the 4.87. Multiply by the run length.
04What size pipe do I need for 10 gpm?
For copper with an 8 ft/s limit, 3/4 inch is the smallest size that fits 10 gpm, at about 6.6 ft/s. It loses about 12.8 psi per 100 feet, so on a long run many plumbers step up to 1 inch, which runs at about 3.9 ft/s and loses about 3.5 psi per 100 feet. Use the calculator with your own length and limits.
05Is PEX smaller inside than copper?
For the same nominal size PEX has a smaller inside diameter than type L copper, so it runs faster and loses more pressure. That is why the calculator shows a larger loss for PEX at the same size.
06Does this include fittings and elbows?
No. Enter a developed length that includes extra length for fittings if you want them counted. A common approach is to add an allowance for each elbow and valve using the manufacturer's equivalent length.
07Does this replace the plumbing code?
No. It shows velocity and friction loss for a known flow. Codes size supply piping by fixture units and available pressure, and the local code decides the required size.
08Can I put the result on an invoice?
Yes. Use Add to an invoice to open the free invoice maker with the pipe size and length as a line. Enter your rate and download the PDF.
09What is water pipe sizing?
Water pipe sizing is choosing a pipe diameter that carries the required flow without excessive water speed or pressure loss. Pipe sizing for a build is set by the plumbing code; this calculator shows the velocity and friction loss behind the choice.
Ready when you are
From pipe size to a paid invoice